电动送风机 Electric Blowers KSB series
|
|
Standard
type model |
Heat-resistance
type model |
Impeller |
Model |
Outlet
flange diameter (mm) |
Phase |
Output
(KW) |
Motor
protection type |
50Hz |
60Hz
|
Material |
Rotational
direction |
Highest
intake temperature |
Estimated
price (yen) |
Highest
intake temperature |
Revolutions
(min-1) |
Max air
flow (m3/min) |
Max static
pressure (KPa) |
Revolutions
(min-1) |
Max air
flow (m3/min) |
Max static
pressure (KPa) |
Casing |
Impeller
(heat-resistant type) |
Turbo |
KSB-400 |
82 |
3 |
0.4 |
fully enclosed fan |
2850 |
12 |
2.10 |
3450 |
12 |
2.10 |
AC2B |
SS400 |
R |
60℃ |
111,200 |
250℃ |
KSB-750 |
123 |
3 |
0.75 |
fully enclosed fan |
2850 |
23 |
2.30 |
3450 |
23 |
2.30 |
AC2B |
SS400 |
R |
60℃ |
114,400 |
250℃ |
KSB-1500 |
123 |
3 |
1.5 |
fully enclosed fan |
2850 |
35 |
2.75 |
3450 |
35 |
2.75 |
AC2B |
SS400 |
R |
60℃ |
148,500 |
250℃ |
KSB-2200 |
148 |
3 |
2.2 |
fully enclosed fan |
2850 |
42 |
3.35 |
3450 |
42 |
3.35 |
AC2B |
SS400 |
R |
60℃ |
194,000 |
250℃ |
KSB-3700 |
175 |
3 |
3.7 |
fully enclosed fan |
2850 |
65 |
4.41 |
3450 |
65 |
4.41 |
AC2B |
SS400 |
R |
60℃ |
257,600 |
250℃ |
KSB-5500 |
JIS5K200A |
3 |
5.5 |
fully enclosed fan |
2920 |
79 |
5.20 |
3510 |
79 |
5.20 |
SS400 |
SS400 |
R |
40℃ |
369,800 |
∵ |
KSB-7500 |
JIS5K200A |
3 |
7.5 |
fully enclosed fan |
2920 |
90 |
5.59 |
3510 |
90 |
5.59 |
SS400 |
SS400 |
R |
40℃ |
413,400 |
∵ |
KSB-750B |
123 |
3 |
0.75 |
fully enclosed fan |
2850 |
15 |
2.10 |
3450 |
18 |
3.00 |
AC2B |
SS400 |
R |
60℃ |
120,200 |
250℃ |
KSB-1500B |
123 |
3 |
1.5 |
fully enclosed fan |
2850 |
24 |
2.75 |
3450 |
28 |
3.90 |
AC2B |
SS400 |
R |
60℃ |
156,000 |
250℃ |
KSB-2200B |
148 |
3 |
2.2 |
fully enclosed fan |
2850 |
32 |
3.15 |
3450 |
38 |
4.50 |
AC2B |
SS400 |
R |
60℃ |
203,800 |
250℃ |
KSB-3700B |
175 |
3 |
3.7 |
fully enclosed fan |
2850 |
45 |
3.78 |
3450 |
52 |
5.40 |
AC2B |
SS400 |
R |
60℃ |
270,500 |
250℃ |
|
|
KSB series is a multipurpose electric
blower with large air flow and wide model range. Electric machinery
unit and casing unit are separate, which prevents water and dust
from invading the bearing. Capable of continuous stable operation
up to 60℃. (Excludes KSB-5500/7500)
NOTICE- If the intake temperature is above 60℃, please use the heat-resistant type model
(HT model) |
|
- Driers
- Milling machines
- Incinerators
|
- Tea processing machinery
- Cardboard machines
- Handling objects, dust collection,